中国化工网首页 >> 化工助手 >> 化学配方数据库
配方类型: |
METAL TREATMENTS |
配方说明: |
Citric/Persulfate Desmutter for Aluminum (No.2) |
配方组成: |
Ferric Sulfate/0.5 Ammonium Persulfate/5.0 Water/84.5 Ammonium Bifluoride/0.1 Citric Acid (anhyd.)/10.0 |
配制方法: |
Note: This formula is considerably more aggressive than Formula No.1. The persulfate must be replenished daily. Use at room temperature with vigorous agitation. Note: Citric acid is used in conjunction with persulfate salts for the removal of black smut from aluminum-copper alloys after cleaning with caustic or a nonalkaline cleaner. The persulfate oxidizes the copper to a soluble form. The citric acid then chelates the copper preventing redeposition on the aluminum. These systems do not attack the base metal aluminum. |
|